www.vivotek.com
mode
Drive the digital output
Note: This request requires the privilege of viewer.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/dido/setdo.cgi?do1=<state>[&do2=<state>]
[&do3=<state>][&do4=<state>][&return=<return page>]
Where state is 0, 1. “0” means inactive or normal state while “1” means active or
triggered state.
PARAMETER VALUE DESCRIPTION
0 – inactive, normal state
do<num>
0, 1
1 – active, triggered state
return
<return page> Redirect to the page <return page> after the
parameter is assigned. The <return page> can be
a full URL path or relative path according the
current path. If you omit this parameter, it will
redirect to an empty page.
Example: Drive the digital output 1 to triggered state and redirect to an empty page
http://myserver/cgi-bin/dido/setdo.cgi?do1=1